Editor’s Review8.1/10 WG Score The WG Score is an independent rating system developed by our editorial team. Scores range from 0 to 10 and are based on data collected across performance, value, reliability, and user feedback – free from any influence by manufacturers or sales partners. We encourage readers to share their experiences in the product reviews section. Learn more ›

Our editorial team weighed WEN's published specifications and how it stacks up against similar products in the generators category. What stands out: Dual Fuel Flexibility, Automatic CO Protection, and RV & Transfer-Switch Ready Outlets. Where it falls short: Heavy, Needs Two People and Lower Runtime on Propane. That puts it at 8.1/10 on our WG Score – an excellent, well-rounded option.

TristanReviewed byTristan

How backup generators work comes down to one chain: an engine burns fuel and spins an alternator, and a transfer switch moves your house onto that power, usually within 10 to 30 seconds of an outage. Standby units do this automatically. Portable units need you to start them and connect circuits safely.

What is inside a backup generator?

Every backup generator has the same core parts, whether it is a $500 portable or a permanent unit beside your house.

  • Engine: burns gasoline, propane, natural gas or diesel and turns a shaft.
  • Alternator: the shaft spins magnets past copper windings. This electromagnetic induction creates alternating current (AC).
  • Governor or controller: holds engine speed steady so output stays near 120/240 volts and 60 Hz.
  • Fuel system and cooling: deliver fuel and carry off heat.
  • Control panel or board: starts and stops the engine and watches for faults like low oil.

Inverter generators add one step. They make raw AC, convert it to DC, then rebuild clean AC electronically. That lets the engine change speed with the load, which saves fuel and runs quieter. Conventional models run at a fixed speed instead.

What happens between a power outage and lights back on?

On a standby generator with an automatic transfer switch, the sequence below is typical. Exact delays depend on the brand and settings, so check your manual.

  1. Outage sensing: the switch monitors utility voltage and frequency. If they drop out of range, a timer starts. Many units wait about 3 to 10 seconds so a brief flicker does not trigger a start.
  2. Engine start: the controller cranks the engine, much like a car starter.
  3. Warm-up and stabilizing: the engine reaches speed, and voltage and frequency settle.
  4. Transfer: only after generator output is acceptable does the switch disconnect your house from the grid and connect it to the generator.
  5. Running: your selected circuits, or the whole house, run on generator power.
  6. Retransfer and shutdown: when utility power returns and holds steady, the switch moves the house back to the grid. The generator then runs a short cool-down and shuts off.

Expect roughly 10 to 30 seconds of darkness from outage to power. Computers without a battery backup will still reboot during that gap. A small UPS on your router and desktop covers it.

What does an automatic transfer switch do?

The automatic transfer switch (ATS) is the part that makes a standby system safe and hands-free. It has three jobs: sense the utility, control the timing, and physically switch your wiring between two sources.

Its most important job is isolation. The house is never connected to the grid and the generator at the same time. Without that, generator power can flow backward through your service lines, called backfeed. That can electrocute a utility lineworker repairing the outage and can destroy your generator.

The National Electrical Code (NEC 702.5) requires transfer equipment that prevents interconnection of utility and generator power. In practice that means a listed automatic transfer switch (UL 1008) or a manual transfer switch or interlock kit approved for your panel. Your local inspector has the final say.

Systems built around this switch are what we compare in our guide to whole-home backup generators.

Standby vs portable generators: how each one starts and connects

Standby (permanent)Portable
StartingAutomatic after outageYou start it by hand or with a button
ConnectionWired to your panel through an ATSExtension cords, or a transfer switch or interlock
FuelNatural gas or propane line or tankGasoline, propane or dual fuel
Typical outputAbout 10 to 22 kW for a whole home (model dependent)About 2 to 12 kW
InstallLicensed electrician, permitsNone for cords; electrician for panel hookup
Where it losesHigher cost, needs installationManual, needs refueling, must be moved and set up

Choose standby if you are often away, have medical equipment, or have frequent long outages. Choose portable if outages are short and you only need a fridge, lights and a few circuits.

If you go portable, our portable generators for home backup roundup covers the main options. If noise matters to you or your neighbors, look at inverter generators for home backup.

Which fuel should a backup generator use?

FuelMain advantageMain drawback
Natural gasContinuous supply from the utility line, no refuelingDepends on the gas line staying in service; lower output than propane in many engines
PropaneStores for years, runs cleanRuntime limited by tank size; you must refill
DieselEfficient under load, common on larger unitsFuel degrades and must be rotated
GasolineEasy to find in normal timesGoes stale in months without stabilizer; hard to find in widespread outages

Dual fuel portables run on gasoline or propane, which gives you a backup if one fuel runs short. See our picks for dual fuel generators for home backup and portable propane generators. Runtime per tank or per gallon varies by model and load, so check the manufacturer’s runtime chart at 50% load.

How big a backup generator do you need?

Add up the running watts of everything you want on at once, then add the single largest extra starting surge. Motors in fridges, sump pumps, well pumps and air conditioners surge for a second or two when they start. The wattages below are typical. Always use the nameplate or manual for your appliances.

Worked example (essential circuits):

  • Refrigerator: 700 running (about 2,200 starting)
  • Furnace blower: 800 running
  • Sump pump: 800 running (about 2,400 starting)
  • Lights, router, phone chargers: 400 running

Running total: 2,700 watts. The largest surge is the sump pump or fridge, so add roughly 1,600 extra watts (2,400 minus 800). Peak need: about 4,300 watts. A generator rated around 5,000 starting and 4,000 running watts handles this if the motors do not start together. Our 4,000 to 7,000 watt gas generator guide fits this range.

Whole-house standby units are usually sized 10 to 22 kW. A central air conditioner is the biggest swing factor. A load calculation by an electrician is the safest way to size one.

Decision rule: if the generator is wired to a panel, choose for the circuits you picked, not for the whole house. A smaller unit with a load-managed panel often covers what you need.

Testing, maintenance and safety rules

Standby generators typically run a short self-test on a schedule, often weekly for 5 to 20 minutes. This keeps the battery charged and exposes problems before an outage. Portable units should be started and run under load at least once a month, with fresh fuel.

  • Service: change oil and filters on the manufacturer’s interval, often every 100 to 200 hours or yearly. Check your manual.
  • Battery: test it yearly. A dead starter battery is a common reason standby units fail to start.
  • Fuel: add stabilizer to gasoline and rotate it. Never refuel a hot engine.

Safety rules that matter:

  • Never run a generator indoors, in a garage, or near windows, doors or vents. Carbon monoxide can kill within minutes. Put battery or plug-in CO alarms with battery backup on every level.
  • Never plug a generator into a wall outlet with a double-ended cord. That is backfeeding. Use an ATS or a listed interlock.
  • Hire a licensed electrician for any panel connection and pull the permit. Rules vary by city and county.
  • Follow the manufacturer’s clearance distances and local code from windows, doors and walls. Many manuals call for about 5 feet from openings, but verify your own.

Common mistake: buying by peak watts alone and forgetting fuel supply. A big generator with no fuel is only a lawn ornament.

If you want no fuel or exhaust at all for small loads, a battery backup generator can run a fridge, router and lights for hours. Capacity varies by model.

Our Top Picks

Ready to shop? These are the top-rated options from our hands-on roundup, Best Portable Generators For Home Backup Power of 2026.

Editor's Pick
WEN GN5602X 5600W Portable Generator Electric Start RV-Ready CO Sensor 4500 Running Watts
WEN

WEN GN5602X 5600W Portable Generator Electric Start RV-Ready CO Sensor 4500 Running Watts

Limited Time
WEN DF8000X 8000-Watt Dual Fuel Portable Generator Electric Start RV Ready with CO Watchdog
WEN

WEN DF8000X 8000-Watt Dual Fuel Portable Generator Electric Start RV Ready with CO Watchdog

As an Amazon Associate we earn from qualifying purchases. Product prices and availability are accurate as of the date/time indicated.

Frequently Asked Questions

How long does a standby generator take to turn on after an outage?

Most standby units start and transfer power within about 10 to 30 seconds. That includes a short delay to confirm the outage, engine start, and a wait for stable voltage. Exact timing depends on the brand and settings, so check your manual.

Can a backup generator power a whole house?

Yes, if it is sized for the load. Whole-house standby units are commonly 10 to 22 kW. A central air conditioner, electric range and dryer drive the size up. An electrician can run a load calculation to confirm what your home needs.

How long can a standby generator run continuously?

It depends on the model and fuel supply. Units on natural gas can run as long as gas flows, though many makers recommend periodic oil checks and service during long runs. Propane units run until the tank is empty. Check the manual.

Do I need a permit to install a backup generator?

Usually yes. Permanent generators and transfer switches typically require electrical and sometimes gas or mechanical permits and an inspection. Rules vary by city and county, so ask your local building department before you buy or install.

{“@context”: “https://schema.org”, “@type”: “FAQPage”, “mainEntity”: [{“@type”: “Question”, “name”: “How long does a standby generator take to turn on after an outage?”, “acceptedAnswer”: {“@type”: “Answer”, “text”: “Most standby units start and transfer power within about 10 to 30 seconds. That includes a short delay to confirm the outage, engine start, and a wait for stable voltage. Exact timing depends on the brand and settings, so check your manual.”}}, {“@type”: “Question”, “name”: “Can a backup generator power a whole house?”, “acceptedAnswer”: {“@type”: “Answer”, “text”: “Yes, if it is sized for the load. Whole-house standby units are commonly 10 to 22 kW. A central air conditioner, electric range and dryer drive the size up. An electrician can run a load calculation to confirm what your home needs.”}}, {“@type”: “Question”, “name”: “How long can a standby generator run continuously?”, “acceptedAnswer”: {“@type”: “Answer”, “text”: “It depends on the model and fuel supply. Units on natural gas can run as long as gas flows, though many makers recommend periodic oil checks and service during long runs. Propane units run until the tank is empty. Check the manual.”}}, {“@type”: “Question”, “name”: “Do I need a permit to install a backup generator?”, “acceptedAnswer”: {“@type”: “Answer”, “text”: “Usually yes. Permanent generators and transfer switches typically require electrical and sometimes gas or mechanical permits and an inspection. Rules vary by city and county, so ask your local building department before you buy or install.”}}]}