Our editorial team weighed DuroStar's published specifications and how it stacks up against similar products in the generators category. What stands out: 13,000 Peak / 10,500 Running Watts, Tri-Fuel Reliability, and Push-Button Remote Start. Where it falls short: High Noise Level and Heavy, Needs Hand Truck. That puts it at 8.1/10 on our WG Score – an excellent, well-rounded option.
Most whole house generators do not have inverters; standby units use an alternator and voltage regulator instead. That still gives usable power for most electronics, and a few inexpensive add-ons protect the sensitive devices.
How a whole house generator makes power
A standby generator burns natural gas or propane to spin an engine, and the engine turns an alternator. A voltage regulator holds the output voltage steady, and a governor holds engine speed steady so the frequency stays near 60 Hz. There is no inverter anywhere in that chain.
Engine speed is the main design difference between models. Air-cooled units typically run at 3,600 rpm, while larger liquid-cooled units typically run at 1,800 rpm. Because the engine speed is fixed, it runs at the same pitch whether the load is light or heavy.
Common residential standby sizes run from about 7 kW to 26 kW. An automatic transfer switch (ATS) senses the outage, starts the engine and moves your panel onto generator power, typically within about 10 to 30 seconds.
Alternators scale to large outputs cheaply, which is why this design dominates whole-house sizes. Inverter designs are most common in small portable units.
Inverter generator vs standby generator side by side
An inverter generator makes alternating current, converts it to direct current, then rebuilds clean AC electronically. A standby generator sends the alternator output straight to your house. The table shows what that changes in practice. For the full portable-side comparison, see our guide on inverter vs conventional generators.
| Feature | Standard standby generator | Portable inverter generator |
|---|---|---|
| Power path | Engine, alternator, regulator, house | Engine, alternator, AC to DC, inverter, house |
| Engine speed | Fixed: 3,600 rpm air-cooled, 1,800 rpm liquid-cooled (typical) | Rises and falls with the load |
| Typical output class | About 7 to 26 kW | About 2 to 7 kW |
| Fuel | Natural gas or propane from a fixed line or tank | Mostly gasoline; some dual-fuel and tri-fuel models |
| Connection | Permanent, through an automatic transfer switch | Extension cords, or a manual transfer switch or interlock |
| Starts during an outage | Automatically | You start it and refuel it |
Where each one loses: the standby unit is the louder, more expensive and permanent choice, and its power is not electronically rebuilt. The inverter unit cannot carry a whole house with electric heat, a large air conditioner or an electric range.
Is standby generator power safe for electronics?
For a properly maintained standby unit, generally yes. The quality of the power is described by total harmonic distortion (THD), the percentage of the waveform that deviates from a clean sine wave. Lower is cleaner.
Secondary sources commonly cite about 1 to 3 percent THD for inverter generators, under 5 percent for standby generators with a quality alternator and regulator, and 8 to 25 percent for conventional portable generators. Treat those as general figures. Older units can run higher, and only the manufacturer’s spec sheet for your exact model is reliable.
Modern computers, TVs and chargers use switching power supplies built to tolerate some distortion. The bigger risks are brief voltage and frequency swings when a large motor starts, or a failing regulator. Liquid-cooled 1,800 rpm units are generally credited with steadier output and longer life than air-cooled ones, but confirm that against the published specs.
Do whole house generators have inverters? The exceptions
Some manufacturers sell variable-speed or inverter-based models, but they are the exception and mostly sit in smaller sizes. Do not assume a standby unit has one; the spec sheet will say so explicitly.
Three product types get blurred together, and they are not the same thing:
- Inverter generator: a fuel-burning engine with an electronic AC-DC-AC stage.
- Inverter-based standby or hybrid model: a fuel-burning installed unit that includes inverter technology. Check the maker’s spec sheet.
- Battery and inverter system: stored energy converted to AC, with no engine at all. A system such as Generac PWRcell is this type. It runs until the battery is drained, then needs solar or the grid to recharge.
A battery system can cover a few circuits silently overnight. It does not replace a generator for multi-day outages unless it is paired with solar or a generator.
| Option | Where the energy comes from | Runs how long |
|---|---|---|
| Standby generator | Natural gas or propane line or tank | As long as fuel supply lasts |
| Portable inverter generator | Gasoline or dual-fuel tank | One tank per refill |
| Battery and inverter system | Stored battery charge | Until the battery is empty |
How to protect sensitive electronics on a standby generator
You do not need to replace the generator to get clean power at the devices that matter. Protect those devices, and leave the rest of the house on standard generator power.
- Add whole-house surge protection. A licensed electrician installs it at the main panel, and it covers both utility and generator power.
- Put a plug-in UPS on computers, routers and storage drives. A UPS rebuilds its output from a battery, so it covers the 10 to 30 second transfer gap and smooths voltage dips.
- Load-test the system before you rely on it. Run a transfer test with the normal household load on, and watch for flickering lights or devices that reboot.
Inverter-driven HVAC equipment and smart appliances contain control boards, so give them the same surge protection. Size the generator from the appliance’s published running and starting watts, not from a guess.
Partial home backup with a portable inverter generator
If you only need essentials, a portable inverter generator can deliver the cleanest power for the lowest cost. It runs a short list of circuits through a manual transfer switch or interlock installed by an electrician, or through extension cords. Our roundup of the best inverter generators for home backup covers models that fit this job.
Worked example (typical values; check your own labels):
- Refrigerator: 700 W running, 2,100 W starting
- Furnace blower: 600 W
- LED lights: 100 W
- Router and computer: 150 W
Running total: 700 + 600 + 100 + 150 = 1,550 W. The peak happens when the refrigerator compressor starts: 1,550 + (2,100 – 700) = 2,950 W. You need a generator rated for at least 1,550 W running and 2,950 W starting, which fits the 2 to 7 kW portable class.
Add the well pump, a window air conditioner or an electric water heater and the peak climbs past what most portable inverter units supply. That is the point where a standby generator makes sense.
What to check on a standby generator spec sheet
Spec sheets answer the inverter question in seconds if you know the lines to read. Ask the dealer for the numbers in writing if the brochure leaves them out.
- THD at rated load. If the manufacturer does not publish it, ask for it.
- Output on your fuel. Natural gas and propane ratings can differ on the same model.
- Motor starting capability. Look for the largest motor, such as your air conditioner compressor, that the unit can start.
- Voltage regulation. The percentage the output may drift under load.
- Cooling and speed. Air-cooled or liquid-cooled, and the rpm.
- Transfer switch rating. The amp rating must match your panel and the circuits you want powered.
- Inverter wording. If it does not say inverter, assume an alternator-only unit.
For safety, have a licensed electrician install the generator and transfer switch to prevent backfeeding utility lines, and follow the National Electrical Code and local permit rules. Keep the unit outdoors and set clearances from windows, doors and vents exactly as the manual and local code require. Install CO alarms in the home.
If your priority is inverter-quality power from a movable unit, compare models in our best whole home inverter generators list.
Our Top Picks
Ready to shop? These are the top-rated options from our hands-on roundup, Best Home Backup Power Generators of 2026.
Honda EU2200iTAN 2200W Super Quiet Portable Inverter Generator with CO-Minder - Ideal for Camping, RV, Home Backup
Honda EU2200i 2200W Super Quiet Inverter Generator - Portable Gas Power for Camping, RV & Home Backup, 8.1H Runtime
DuroStar DS13000MXT 13,000W Tri-Fuel Portable Generator - Gas, Propane, Natural Gas, Remote Start, Whole Home Backup
As an Amazon Associate we earn from qualifying purchases. Product prices and availability are accurate as of the date/time indicated.
Frequently Asked Questions
Can I add an inverter to my standby generator?
Not as a fix for the generator itself. You can put a UPS or power conditioner on individual devices, which does the same job where it matters. Ask the manufacturer and a licensed electrician before wiring anything between the generator and your panel.
Is a liquid-cooled standby generator cleaner than an air-cooled one?
Typically somewhat steadier, because liquid-cooled units run at about 1,800 rpm instead of 3,600 rpm. Neither type is an inverter. Compare the published THD and voltage regulation on each model’s spec sheet rather than assuming.
Can a battery system replace a whole-house generator?
Only for short outages or a small set of circuits. A battery runs until it is empty. For multi-day outages you need a generator or enough solar to recharge it, so size the battery to your essential loads.
Will an inverter-driven air conditioner or mini-split run on a standby generator?
Yes, if the generator covers its running watts and its starting watts as listed by the maker. These units are gentler on startup, but the control boards still benefit from whole-house surge protection.
{“@context”: “https://schema.org”, “@type”: “FAQPage”, “mainEntity”: [{“@type”: “Question”, “name”: “Can I add an inverter to my standby generator?”, “acceptedAnswer”: {“@type”: “Answer”, “text”: “Not as a fix for the generator itself. You can put a UPS or power conditioner on individual devices, which does the same job where it matters. Ask the manufacturer and a licensed electrician before wiring anything between the generator and your panel.”}}, {“@type”: “Question”, “name”: “Is a liquid-cooled standby generator cleaner than an air-cooled one?”, “acceptedAnswer”: {“@type”: “Answer”, “text”: “Typically somewhat steadier, because liquid-cooled units run at about 1,800 rpm instead of 3,600 rpm. Neither type is an inverter. Compare the published THD and voltage regulation on each model’s spec sheet rather than assuming.”}}, {“@type”: “Question”, “name”: “Can a battery system replace a whole-house generator?”, “acceptedAnswer”: {“@type”: “Answer”, “text”: “Only for short outages or a small set of circuits. A battery runs until it is empty. For multi-day outages you need a generator or enough solar to recharge it, so size the battery to your essential loads.”}}, {“@type”: “Question”, “name”: “Will an inverter-driven air conditioner or mini-split run on a standby generator?”, “acceptedAnswer”: {“@type”: “Answer”, “text”: “Yes, if the generator covers its running watts and its starting watts as listed by the maker. These units are gentler on startup, but the control boards still benefit from whole-house surge protection.”}}]}