Editor’s Review8.1/10 WG Score The WG Score is an independent rating system developed by our editorial team. Scores range from 0 to 10 and are based on data collected across performance, value, reliability, and user feedback – free from any influence by manufacturers or sales partners. We encourage readers to share their experiences in the product reviews section. Learn more ›

Our editorial team weighed WEN's published specifications and how it stacks up against similar products in the generators category. What stands out: Clean Sine Wave Output, Parallel-Ready, and Compact, Lighter Than Rivals. Where it falls short: Recoil Start Only and Open-Frame, Louder Design. That puts it at 8.1/10 on our WG Score – an excellent, well-rounded option.

TristanReviewed byTristan

Drain the old gas and refill with fresh fuel before starting a generator; stale fuel clogs the carburetor. If the gas fails the jar test below, or you cannot say how long it has sat, do not run it.

Should you run a generator on old gas at all?

Most small engines will fire on stale gas for a while, which is why it is tempting. The risk is what the fuel leaves behind: varnish and gum that clog the carburetor’s tiny jets and, in ethanol blends, absorbed water that can corrode metal parts and degrade rubber and plastic fuel components.

Manufacturer manuals address this in their storage sections: before the unit sits, either drain the fuel system or treat fresh fuel with stabilizer. Your manual’s wording for your model is the final word.

Decision rule: if the gas fails any check in the next section, or you cannot say how long it has sat, drain it. Skip draining only when the fuel passes every check and is within the manual’s storage window.

How to tell if the gas has gone bad

Do a jar test. Pour a cup from the tank into a clear glass jar, let it settle for a few minutes, and hold it up against a white background. Then smell it: fresh gasoline smells sharp and familiar, not sour.

What you see or smellWhat it meansAction
Sour or varnish-like smellFuel has oxidizedDrain
Dark amber or brown colorGum and varnish have formedDrain
Cloudy bottom layer or separate liquid in the jarEthanol has absorbed water and separatedDrain; never reuse
Flakes or particlesDebris or rust from the tankDrain, then inspect the fuel filter

Age alone is a weak test. As a rough estimate, untreated gasoline starts to degrade after about 3 to 6 months in a sealed can, and ethanol blends can turn in as little as about 3 months. Heat and a partly empty vented tank speed that up. Treat the figure as a guide, not a guarantee.

How to drain old gas from the tank and carburetor

  1. Shut the engine off and let it cool completely. Work outdoors on level ground, away from flames, pilot lights and sparks.
  2. Turn the fuel valve off and pull the spark plug wire off the plug so the engine cannot fire while you work.
  3. Empty the tank with a hand siphon pump into an approved gasoline container. Never siphon by mouth.
  4. Set a catch container under the carburetor and loosen the bowl drain screw. Turn the fuel valve on briefly to flush the bowl until the fuel runs clear, then turn the valve off and tighten the screw.
  5. Wipe up spills and let fumes clear before going near the engine again.
  6. Take the old fuel in a sealed, labeled container to a household hazardous waste site or collection program. Never pour it on the ground, down a drain or in the trash, and do not put it in another engine.
  7. Refill with fresh gasoline that meets the ethanol limit printed on the fuel cap or in the manual (small-engine manuals commonly cap it at 10%).

Exception: if your carburetor has no drain screw, the manual or a service shop will show the bowl removal procedure. Do not improvise it.

Steps to start a generator after the old gas is out

  1. Check the oil level. Low oil can trip the automatic shutoff and keep the engine from starting.
  2. Reconnect the spark plug wire firmly.
  3. Unplug everything and switch the breaker off so the engine starts with no load.
  4. Set the generator outdoors with the exhaust pointed away from the house, and turn the fuel valve on.
  5. Close the choke for a cold start and switch the engine on. Inverter models usually choke automatically, so skip this step on those.
  6. Pull the cord firmly, or use the electric start in short bursts of a few seconds with rests between. Expect a few extra pulls while the carburetor refills.
  7. As the engine warms, ease the choke open in stages until it runs smoothly.
  8. Let it run unloaded for about 15 minutes so fresh fuel reaches the whole fuel system, then add your load.

If it still won’t start or keeps dying

Work down this list in order. Each step is cheaper and faster than the next.

StepQuick checkRough time (estimate)
Spark plugPull it and look: wet, black or oily means fouled, so replace itAbout 10 minutes
Air filterDirty or oil-soaked element needs cleaning or replacingAbout 5 minutes
Fuel at the bowlWith the fuel valve on, loosen the drain screw; a steady stream means the line is openAbout 10 minutes
Carb cleaner spray testOne short spray into the air intake; if it fires briefly then dies, fuel is not reaching the engineAbout 5 minutes
Remove and clean the carburetorClean jets and passages; use a rebuild kit if parts are corroded or gaskets are hardAbout 1 to 2 hours the first time

Keep the spray short and sparing because carb cleaner is flammable, and keep sparks away. If the engine runs only while you are spraying, the problem may be a stuck fuel shutoff solenoid (on models that have one) rather than a clogged jet.

Stop and call a service shop if there is no spark with a new plug, the carburetor leaks fuel, the engine knocks or smokes heavily, or you are not confident reassembling the linkage. For causes unrelated to fuel, use the generator won’t start troubleshooting checklist.

Can you mix old gas with fresh gas or add something to fix it?

Manuals give no dilution ratio for stale fuel, so none is offered here. Mixing lowers the concentration but leaves the varnish and any water in the tank, and you end up with a tank you cannot judge by smell or color. Never dilute gas that failed the jar test.

Stabilizer is for fresh fuel only; it will not reverse gas that has already gone bad. A fuel-system cleaner may loosen light varnish, but follow the bottle’s dose and the manual, and do not expect it to clear a carburetor that is already clogged.

Keep old gas from happening again

  • Add stabilizer to fresh fuel at the label dose, then run the engine a few minutes so treated fuel reaches the carburetor.
  • Buy only the fuel you expect to use, within the ethanol limit in the manual.

If the engine still will not start after a fresh-fuel refill, use the generator won’t start troubleshooting checklist.

Our Top Picks

Ready to shop? These are the top-rated options from our related roundup, Best Small Gas Powered Generators of 2026.

Best Seller
Honda EU2200iTAN 2200W Super Quiet Portable Inverter Generator with CO-Minder - Ideal for Camping, RV, Home Backup
Honda

Honda EU2200iTAN 2200W Super Quiet Portable Inverter Generator with CO-Minder - Ideal for Camping, RV, Home Backup

Editor's Pick
Westinghouse iGen2800 2800 Peak Watt Super Quiet Lightweight Portable Inverter Generator - Gas Powered, Parallel Ready

Westinghouse iGen2800 2800 Peak Watt Super Quiet Lightweight Portable Inverter Generator - Gas Powered, Parallel Ready

As an Amazon Associate we earn from qualifying purchases. Product prices and availability are accurate as of the date/time indicated.

Related reading: A-iPower AP10000E Electric Start Portable Gas Generator Review 2026 · Best Electric Start Generators For Home Use Review 2026

Frequently Asked Questions

Can I add fresh gas to a half-empty tank of old gas?

No. Fresh fuel dilutes the old gas but leaves the varnish and any water in the tank. Drain the tank and carburetor, then refill.

Should I test the fuel in the tank or in the carburetor bowl?

Both. Fuel in the bowl can be older than what is in the tank, so check a sample from each. If either looks or smells bad, drain both.

Does ethanol-free gas never go bad?

No. Ethanol-free gasoline still oxidizes and forms varnish over time. It avoids the water absorption and phase separation that ethanol blends suffer, so it lasts longer but still needs stabilizer for storage.

Can I use the old gas in a lawn mower instead?

It is not a good idea. Small mower engines have carburetors that varnish clogs the same way. Take bad fuel to a household hazardous waste site.

{“@context”: “https://schema.org”, “@type”: “FAQPage”, “mainEntity”: [{“@type”: “Question”, “name”: “Can I add fresh gas to a half-empty tank of old gas?”, “acceptedAnswer”: {“@type”: “Answer”, “text”: “No. Fresh fuel dilutes the old gas but leaves the varnish and any water in the tank. Drain the tank and carburetor, then refill.”}}, {“@type”: “Question”, “name”: “Should I test the fuel in the tank or in the carburetor bowl?”, “acceptedAnswer”: {“@type”: “Answer”, “text”: “Both. Fuel in the bowl can be older than what is in the tank, so check a sample from each. If either looks or smells bad, drain both.”}}, {“@type”: “Question”, “name”: “Does ethanol-free gas never go bad?”, “acceptedAnswer”: {“@type”: “Answer”, “text”: “No. Ethanol-free gasoline still oxidizes and forms varnish over time. It avoids the water absorption and phase separation that ethanol blends suffer, so it lasts longer but still needs stabilizer for storage.”}}, {“@type”: “Question”, “name”: “Can I use the old gas in a lawn mower instead?”, “acceptedAnswer”: {“@type”: “Answer”, “text”: “It is not a good idea. Small mower engines have carburetors that varnish clogs the same way. Take bad fuel to a household hazardous waste site.”}}]}