Our editorial team weighed 's published specifications and how it stacks up against similar products in the generators category. What stands out: Exceptionally Quiet at 52dBA, 12-Hour Runtime, and Lightweight & Portable. Where it falls short: Small 0.98-Gallon Tank and Parallel Cord Sold Separately. That puts it at 8.5/10 on our WG Score – an excellent, well-rounded option.
To get a generator started, open the fuel valve, set the engine switch to ON, close the choke for a cold engine, pull the cord or press start, open the choke gradually, and wait about 2 to 3 minutes before plugging in loads. The steps below cover each design, the pre-start checks, and the common reasons a generator refuses to start.
What should you check before starting a generator?
Most failed starts trace back to something you can see in two minutes. Work through this list on level ground with the engine off and cool.
- Oil level: Check the dipstick or fill port. Many portable units have a low-oil shutoff that stops the engine or keeps it from starting when the level is low. Use the oil type and amount in your manual.
- Fuel level and age: Use fresh gasoline of the grade the manual specifies. Stale gas is a common cause of hard starting, and the stabilizer label tells you how long treated fuel lasts (varies by model; check the label or manual).
- Nothing plugged in: Unplug every cord and switch off the generator’s breakers so the engine starts with no load.
- Air filter and spark plug cap: Confirm the filter is in place and the plug wire is seated firmly on the plug.
- Battery (electric-start units): Make sure the battery is connected and charged. Some fuel-injected models need a charged battery to run the fuel system even when you use the recoil cord (varies by model; check the manual).
Never add fuel while the engine is running or hot. Shut it off, let it cool, and refuel from an approved gasoline container away from sparks, flames and hot surfaces. Wipe up spills before starting.
Where should you put a generator before you start it?
Place it outdoors on level, dry ground, with the exhaust pointed away from the house. Your manual sets the minimum distance, so check it first. The Consumer Product Safety Commission also advises keeping a running portable generator at least 20 feet from the home and away from windows, doors and vents; use whichever distance is greater.
Never run it in a garage, basement, shed or under an open door, even for a few minutes. Carbon monoxide builds up fast and you cannot smell it. Keep working CO alarms inside the house. Our portable generator safety rules cover rain protection, grounding and fueling in more detail.
How to get a generator started: the 6 steps
These steps fit most portable gas generators. Your manual overrides them if the order differs.
- Turn the fuel valve on. On many models it is a lever near the carburetor or tank. Fuel-injected units may not have one.
- Set the engine switch to ON/RUN. On many models this switch controls ignition. On electric-start models, a key may go to RUN first.
- Set the choke for a cold engine. Move it to CLOSED (full choke). Skip this if the engine is already warm.
- Start the engine. For recoil, hold the handle, pull slowly until you feel resistance, then pull firmly and smoothly. For electric start, press the button or turn the key in short bursts, resting between tries so you do not drain the battery.
- Open the choke gradually. As the engine smooths out, move the choke toward RUN in steps. If it stalls, close it slightly and wait a few seconds.
- Let it run with no load for about 2 to 3 minutes. The engine should hold a steady sound before you connect anything (varies by model; check the manual).
Choke and starting differences by design
| Design | Cold start | Warm restart |
|---|---|---|
| Lever or knob choke | Choke closed, then open gradually | Choke open or partly closed |
| Primer bulb | Press the bulb the number of times the manual lists, then pull | Usually skip or press once |
| Auto-choke | No choke control; just pull or press | Same |
| Fuel injection (EFI) | No choke; typically needs a charged battery | Same |
If you want to skip the cord altogether, see our guide to electric start generators for home use.
When can you plug things in?
Plug in only after the engine runs smoothly and the choke is fully open. Then add loads one at a time, starting with the one that draws the biggest startup surge, usually a motor such as a refrigerator compressor or sump pump. Wait a few seconds between each.
Example (illustrative numbers, not a spec): A generator rated 3,500 running watts and 4,375 starting watts. Fridge: 700 running, 2,200 starting. Sump pump: 800 running, 2,400 starting. Lights: 200 running. Assumed order: fridge, then pump, then lights.
- Fridge starts: 2,200 W peak, under 4,375.
- Pump starts with the fridge running: 2,400 + 700 = 3,100 W peak, under 4,375.
- Fridge and pump both running: 700 + 800 = 1,500 W.
- Lights added last: 1,500 + 200 = 1,700 W running, under 3,500.
- Peak check if the lights were already on when the pump starts: 2,400 + 700 + 200 = 3,300 W, still under 4,375.
Get real numbers from each appliance’s nameplate, and see how to size a generator for your home before storm season.
Use grounded, outdoor-rated extension cords sized for the load. To power house circuits, use a transfer switch or interlock installed by a licensed electrician. Never plug the generator into a wall outlet, which backfeeds the grid and can electrocute utility workers.
Why won’t my generator start? Symptom-to-fix table
Before any repair, turn the unit off, let it cool and work on level ground. Pull the spark plug wire before working on the carburetor, filter or fuel parts, and reconnect it before you retry the start.
| Symptom | Likely cause | Fix |
|---|---|---|
| No crank, no click (electric start) | Dead or disconnected battery, switch off | Charge or replace the battery; try the recoil cord if the model allows |
| Clicks but won’t crank | Weak battery or bad solenoid | Charge the battery first; have the solenoid checked per the manual |
| Cranks, won’t fire | Stale fuel, fuel valve off, fouled spark plug, choke wrong | Open the valve, set the choke, replace old fuel; with the wire off, inspect the plug and clean or replace it |
| Cord pulls normally but engine never catches or quits at once | Low-oil shutoff (the cord does not feel hard) | Add oil to the full mark and retry |
| Cord feels very hard or will not pull | Compression problem or seized engine, not low oil | Stop pulling and take it to a service center |
| Starts then dies | Choke opened too fast, clogged fuel cap vent, dirty carburetor, dirty filter | Reset the choke, open the cap vent, clean the air filter, service the carburetor |
| Surges or hunts | Partly clogged carburetor jet, old fuel | Run with fresh fuel; clean the carburetor if it persists |
| Runs, no power at outlets | Tripped breaker or GFCI | Reset them with all loads unplugged |
Do not spray starter fluid into the intake unless your manual allows it. It can damage some engines and cause a backfire.
How do you start a generator after winter or in the cold?
A generator that sat all winter often has stale fuel that left varnish in the carburetor. Drain the old gas into an approved container, dispose of it as your local rules require, refill with fresh fuel, and try again. If it still will not run, the carburetor probably needs cleaning; our generator won’t start troubleshooting guide has a longer checklist.
In cold weather, thicker oil and fuel make cranking harder. Check the oil grade in your manual for low temperatures, keep the battery charged (cold weakens batteries), and move the unit to a sheltered spot outdoors, still well away from the house. Diesel units can struggle in cold because the fuel thickens; check the manual for winter-grade fuel or additives, and air in the lines may need bleeding.
How do you shut down and store it so it starts next time?
Unplug all loads first, then let the engine run with no load for about 2 to 3 minutes before switching it off. Turn the fuel valve off if there is one, and let the engine cool before moving it.
- Short gaps: Keep the tank mostly full of fresh fuel.
- Longer storage: Add fuel stabilizer following its label, then run the engine a few minutes so treated fuel reaches the carburetor, or drain the fuel per your manual.
- Monthly exercise run (separate from the cool-down above): Start it and run it under light load for 10 to 15 minutes (varies by model; check the manual).
- Each season: Check oil, air filter and spark plug on the schedule in your manual.
Cover it with a vented cover only after it has fully cooled. If yours is old and hard to start each time, a newer electric-start or inverter model may be worth a look.
Our Top Picks
Ready to shop? These are the top-rated options from our hands-on roundup, Best Electric Start Portable Generators of 2026.
Westinghouse iGen2800 2800 Peak Watt Super Quiet Lightweight Portable Inverter Generator - Gas Powered, Parallel Ready
WEN GN5602X 5600W Portable Generator Electric Start RV-Ready CO Sensor 4500 Running Watts
WEN RV-Ready 4000-Watt Open Frame Inverter Generator GN400iM
As an Amazon Associate we earn from qualifying purchases. Product prices and availability are accurate as of the date/time indicated.
Frequently Asked Questions
How many times should I pull the cord before stopping?
Rule of thumb: after about 5 firm pulls with the fuel valve on, the switch on and the choke set correctly, stop. Check oil, fuel and the spark plug instead of pulling repeatedly, which can flood the engine. Stop at once if the cord feels very hard.
Why does my generator die when I plug something in?
The load is usually too big. A motor’s startup surge can exceed the generator’s starting watts, or the total running watts can pass its rating. Unplug everything, let the engine settle, then add loads one at a time, largest surge first, using nameplate numbers.
Can I start a generator in the rain?
Only under a dry, open-sided cover made for generators, or as your manual allows. Keep the exhaust clear and never move it into a garage or other enclosed space. Keep cords and connections off wet ground, and do not handle the unit with wet hands.
Can I restart a generator right after it stalls?
Yes, if it stalled from a choke or load issue. Unplug the loads and wait a few seconds, then restart with the choke open or partly closed. If it ran out of fuel, let it cool before refueling, then follow the 6 steps again.
{“@context”: “https://schema.org”, “@type”: “FAQPage”, “mainEntity”: [{“@type”: “Question”, “name”: “How many times should I pull the cord before stopping?”, “acceptedAnswer”: {“@type”: “Answer”, “text”: “Rule of thumb: after about 5 firm pulls with the fuel valve on, the switch on and the choke set correctly, stop. Check oil, fuel and the spark plug instead of pulling repeatedly, which can flood the engine. Stop at once if the cord feels very hard.”}}, {“@type”: “Question”, “name”: “Why does my generator die when I plug something in?”, “acceptedAnswer”: {“@type”: “Answer”, “text”: “The load is usually too big. A motor’s startup surge can exceed the generator’s starting watts, or the total running watts can pass its rating. Unplug everything, let the engine settle, then add loads one at a time, largest surge first, using nameplate numbers.”}}, {“@type”: “Question”, “name”: “Can I start a generator in the rain?”, “acceptedAnswer”: {“@type”: “Answer”, “text”: “Only under a dry, open-sided cover made for generators, or as your manual allows. Keep the exhaust clear and never move it into a garage or other enclosed space. Keep cords and connections off wet ground, and do not handle the unit with wet hands.”}}, {“@type”: “Question”, “name”: “Can I restart a generator right after it stalls?”, “acceptedAnswer”: {“@type”: “Answer”, “text”: “Yes, if it stalled from a choke or load issue. Unplug the loads and wait a few seconds, then restart with the choke open or partly closed. If it ran out of fuel, let it cool before refueling, then follow the 6 steps again.”}}]}